API 5L X42 Line Pipe

Specifications

Nominal Pipe Size 1/2″ to 48 ” O.D;

Length:5- 12 Meter lengths;

Wall Thickness – Schedule 10 through 160, STD, XS, XXS;

Product Specification Level (PSL) : PSL 1,PSL 2;

Manufacturing process: SSAW, LSAW, ERW welded/ Seamless;

Ends: Plain, beveled ends and threaded ends.

The American Petroleum Institute specification API 5L is designed for transportation systems in the petroleum and natural gas industries for conveying gas, water, and oil. API 5L X42 is a steel grade of API 5L which specifies the manufacture of two product levels (PSL1 and PSL2) and two manufacturing types seamless and welded steel line pipe. WLD Steel also provides internal & external coating like Black paint, varnished, FBE coating, 3LPE coating and all lined pipe on steel pipes as per the customers’ requirement. WLD steel supply and manufactured a large inventory of  API 5L X42 steel pipe in PSL1 and PSL2.

API 5L X42 Equivalent Material

Specification API 5L x42 PSL1 ISO 3183 L290
Grades API 5L PSL2 X42Q
API 5L PSL2 X42R
API 5L PSL2 X42N
API 5L PSL2 X42Q
API 5L PSL2 X42M
ISO 3183 L290Q
ISO 3183 L290R
ISO 3183 L290N
ISO 3183 L290Q
ISO 3183 L290M

Chemical Composition for X42 PSL 1 pipe

Grades C Mn P S
X42 PSL1(Seamless) 0.26 1.30 0.03 0.03
X42 PSL1(Welded) 0.22 1.30 0.03 0.03

Chemical Composition for X52 PSL 2 pipe

Grades C Mn Si P S
X42R PSL2(Seamless) 0.24 1.2 0.40 0.025 0.015
X42N PSL2(Seamless) 0.24 1.2 0.40 0.025 0.015
X42Q PSL2(Seamless) 0.24 1.4 0.45 0.025 0.015
X42M PSL2(Welded) 0.22 1.2 0.45 0.025 0.015

API 5L X42 Mechanical Property

Grades Yield Strength Tensile Strength Elongation,%
API 5L X42 42100 60200 23

Differences between API 5L X42 PSL 1 and PSL 2

PSL PSL1 PSL2
Charpy testing None required Required for all grades
Nondestructive inspection of seamless Only when the purchaser specifies   SR4 SR4 mandatory
Certification Certificates when specified per SR15 Certificates (SR 15.1) mandatory
Traceability Traceable only until all tests are passed, unless SR15 is specified Traceable after completion of tests (SR 15.2) mandatory
Hydrostatic Test Required Required